S&A CW6000DN230H Industrial Water Chiller with Heating Function, for 100W RF Metal or Solid-state Laser, 22KW CNC Spindle, 30W-300W Fiber Laser Cooling

3000W cooling capacity, SS centrifugal pump of multistage type, 1 outlet and 1 inlet.

Item Code: CW-6000DN230H

Unit Price: $1,785.00/set

Finance as low as $50 / mo

Apply to See Distributor Price

Inquire Now

Buyer Protection

S&A CW6000DN230H Industrial Water Chiller with Heating Function, for 100W RF Metal or Solid-state Laser, 22KW CNC Spindle, 30W-300W Fiber Laser Cooling
Buy It Now

S&A CW6000DN230H Industrial Water Chiller with Heating Function, for 100W RF Metal or Solid-state Laser, 22KW CNC Spindle, 30W-300W Fiber Laser Cooling

CAUTIONS

We are authorized as "S&A" brand name product agent.
All of S&A water chillers are certified with design patent. Counterfeiting is not allowed, 
Please recognize S&A logo when you purchase S&A water chillers.

Description

S&A CW-6000 series is high-precision compression refrigeration water chiller, with intelligent temperature control,completed configuration,perfect protection and alarm system.
S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature to avoid producing condensate water and protect the laser tube.You can adjust the water temperature under constant temperature.

Suggestion:
Intelligent temperature control mode for summer
Constant temperature control mode for winter
Note: Cooling water additive is forbidden by express company, so we could not put it into the package. You can buy it from local.

Features:
  • 3000W cooling capacity; optional environmental refrigerant;
  • ±0.5°C precisely temperature control; 
  • The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;
  • Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
  • Multiple power specifications; CE ,RoHS and REACH approval;
  • Long working life and simple operation;
  • Optional heater and water filter.

SPECIFICATION

Model CW-6000DN230H
Voltage AC 1P 110V
Frequency 60Hz
Current 2~11A
Compressor power
1.12KW
1.52HP
Nominal cooling capacity
10724Btu/h
3.145KW
2711Kcal/h
Refrigerant charge 650g
Pump power 0.37-0.75KW
Pump lift 28-53M
Pump flow 70L/min
N.W 72Kgs
G.W 82Kgs
Refrigerant R-410a
Precision ±0.5℃
Reducer Capillary
Protection Overcurrent protection for compressor, flow alarm, over temperature alarm
Tank capacity 15 L
Inlet and outlet Rp1/2''
Dimension 67X47X89 cm (L X W X H)
Package dimension 74X60X109 cm (L X W X H)
CONTOUR AND PARTS INTRODUCTION
 

Independent production of sheet metal.

High precision temperature control system.

Adopt IPG fiber laser for welding and cutting sheet metal. 
Temperature control accuracy can reach ±0.5℃.
 
 

Equipped with water pressure gauges and universal wheels.

Water pressure gauges help monitor the discharge pressure of water pump while univeral wheels facilitate the moving of the chiller.

 
 

Inlet and outlet connector equipped.

Multiple alarm protection.

The laser will stop working once it receives alarm signal from the water chiller for protection purpose.
 
 

Cooling fan of famous brand installed.

Level gauge equipped.

Adopt SAN JU cooling fan with high quality and low failure rate.
 
 

Customized dust gauze available and easy to take apart.

 
Temperature controller panel description:

The intelligent temperature controller does not need to adjust the controlling parameters under normal circumstance. It will self-adjust controlling parameters according to room temperature for meeting equipment cooling requirements.  
User also can adjust the water temperature as needed.

Temperature controller panel description:

  • Indicators of temperature controller working status: 
    COMP         ON, compressor working
    SV               ON, solenoid valve working
    Heating      ON, heating rod working
    INT    Ctrl   ON, controller working in intelligent control mode
    CT     Ctrl    ON, controller working in constant temperature control mode
    PARAM Set ON, controller working in parameters setting mode
    ALM   OUT  ON, alarm output status
    Room Temp ON, displaying room temperature
    ST     DLA     ON, starting up delay status
  • Press ▼ button to show the room temperature, 6 seconds later default display restored.
    (Meanwhile, Room Temp light is on, displaying room temperature.)
  • ▲▼ buttons are for modifying parameters values andbuttons are for switching parameter items.
  • RST button: confirm.
  • SET button: setting function.
 

Alarm function

(1) Alarm Display:
When alarm occurs, the error code and the temperature will be alternately displayed.

(2) To suspend the alarm:
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated.

Alarm and output ports

In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-6000series chillers possesses an unique low flow alarm protection.

(1) Flow alarm output ports and the wiring diagram

(2) Flow alarm causes of circulating cooling water and working state

Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.

Application

Certificate

Warehouse

Test System

Packing

Installation

Open the package to check if the machine is intact and all the necessary accessories are completed.

 

Open the injection port to feed cooling water. (Do not let the water spill over!)

 
Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of cooling water additive (anti-corrosion water aqua). Working in cold north area, it’s better to use noncorrosive antifreeze fluid.

According to system conditions, please connect the water inlet and outlet pipe well.

 

Plug in power, turn on the power switch. (Do not start up without water in the water tank!)

 
(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.
(2) After the first boot, you must immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set value, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start over the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.

Check the water level in the water tank.

 
The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.

Adjust parameters of temperature controller.

 
CW-6000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to page 17, “Operating status and parameters adjustment.”

Cautions

Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded!

 

Please make sure there is stable and normal voltage for the working chiller!

 
As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 210 ~ 240V (110V model is of 100 ~120V). If you do need a wider operating voltage range, customization is available for us.

Unmatched power frequency can cause the chiller damage!

 
Please choose model of 50Hz or 60Hz according to actual circumstance.

To protect the pump, it’s strictly forbidden to run the chiller without water in the storage water tank!

 
The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!

Please be sure that the air inlet and air outlet are in good ventilation!

 
There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.

The filter screen must be regularly cleaned!

 
It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.

Please pay attention to the effect of the condensate water!

 
With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.

Professional use only!

 
The appliance is not to be used by children or persons with reduced physical,sensory or mental capabilities, or lack of experience and knowledge,unless they have been given supervision or instruction,children being supervised not to play with the appliance!

Troubleshooting

Failure Failure Cause Approach
Machine turned on but unelectrified
Power cord is not plugged in place Check and ensure the power interface and the power plug is plugged in place and in good contact.
Fuse burnt-out Replace the protective tube in the power socket on the back of chiller.
Flow Alarm (controller displays E6)use a water pipe directly connect to the water outlet and inlet but still without water flowing Water level in the storage water tank is too low Check the water level gauge display, add water until the level shown in the green area; And check whether water circulation pipe leaks.
Flow Alarm occurs while running with other equipment (controller displays E6),but there is water flowing and no alarm whten use a water pipe directly connected to the chiller water outlet and inlet. Water circulation pipes are blocked or a pipe bending deformation. Check water circulation pipe
Ultra-high temperature alarm (controller displays E2)
Blocked dust gauze, bad thermolysis Unpick and wash the dust gauze regularly
Poor ventilation for air outlet and inlet To ensure a smooth ventilation for air outlet and inlet
Voltage is extremely low or astable To improve the power supply circuit or use a voltage regulator
Improper parameter settings on thermostat To reset controlling parameters or restore factory settings
Switch the power frequently To ensure there is sufficient time for refrigeration (more than 5 minuets)
Excessive heat load Reduce the heat load or use other model with larger cooling capacity
Ultrahigh room temperature alarm (controller displays E1) The working ambient temperature is too high for the chiller To improve the ventilation to guarantee that the machine is running under 40℃.
Serious problem of condensate water Water temperature is much lower than ambient temperature, with high humidity Increase water temperature or to preserve heat for pipeline
Water drains slowly from outfall during water changing Water supply inlet is not open Open the water supply inlet

Model

CW-6000DN

Power Supply

AC 1P 110V, 60Hz

Current

2~11A

Compressor Power

1.12KW

1.52HP

Refrigerating Capacity

10724Btu/h

3.145KW

2711Kcal / h

Refrigerant

R-410a 

Refrigerant Charge

650g

Precision

±0.5℃

Tank Capacity

15L

Reducer

Capillary

Protection

Over current protection for compressor, flow alarm, over temperature alarm

Pump Power

0.37~0.75KW

Maximum Flow

70L / min

Maximum Pumping Lift

28~53M

Inlet and Outlet

Rp1/2"

Net Weight

72kg

Gross Weight

82kg

Product Dimension

26.4" x 18.5" x 35" (670 x 470 x 890mm)

Package Dimension

29" x 23.6" x 42.9" (740 x 600 x 1090mm)

Customer Reviews
Love it! Rate it!
  • Simply write a review of a product and you can get up to 500 Points (Equivalent to $5) for Next Orders.
  • ≥ 120 words + ≥ 3 clear photos = Up to 1000 Points (Equivalent to $10).
  • Show us why you love or how to use the product. Help other shoppers find the right product!
Average Rating: 0
  • Reviews (0)
  • No Reviews

Quick Inquiry for S&A CW6000DN230H Industrial Water Chiller with Heating Function, for 100W RF Metal or Solid-state Laser, 22KW CNC Spindle, 30W-300W Fiber Laser Cooling

Business E-mail:

Name:

Phone:

Message:

Characters:20(Min.) - 2000(Max.)

Verification code:

Top Selling

Get in Touch

9850 6th St Rancho Cucamonga CA 91730

626-342-7605

service@sign-in-global.us

Newsletter

Subscribe to our special offers

Follow us

Follow us on Facebook Follow us on Youtobe
Back to top