Description:
S&A CW-6100BT dual temperature and dual pump series is high-precision compression refrigeration small water chiller,with intelligent temperature control,completed configuration,perfect protection and alarm system.S&A CW-6100BT is able to cool the fiber laser and optic lense at the same time, multiple use for saving cost, space and manual move, quiteconvenient for the user. S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature. With that 1 key solution, customers no longer need to worry about the water temperature adjustment of seasonal changes.
Features:
•One-stop automatic intelligent temperature control: in different environment, user does not need to change setting due to it will automatically switch;
• 4200W cooling capacity; optional environmental refrigerant;
• ±0.5℃ precisely temperature control;
• The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;
• Dual temperature and dual pump to satisfy different needs of fiber laser device and the lens;• With Ion adsorption filtrating and test functions conform to fiber laser device operating requirements;
• Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• Multiple power specifications; CE approval; RoHS approval;
• Long working life and easy operation;
• Optional heater and water filter.
Temperature control panel introduction:
(1). Indicators of temperature controller working status:
COMP ON, compressor working
SV ON, solenoid valve working
Heating ON, heating rod working
INT Ctrl ON, controller working in intelligent control mode
CT Ctrl ON, controller working in constant temperature control mode
PARAM Set ON, controller working in parameters setting mode
ALM OUT ON, alarm output status
Room Temp ON, displaying room temperature
ST DLA ON, starting up delay status
(2). Press ▼key to show the room temperature, 6 seconds later default display restored. (Meanwhile, Room Temp light is on, displaying room temperature.)
(3). ▲ ▼ keys are for modifying parameters values and < > keys are for switching parameter items.
(4). RST key: confirm
(5). SET key: setting function